Avantra WebUI Configuration

You can configure the Avantra WebUI runtime environment by setting the values for a number of parameters. Some of the parameters can be adjusted while the WebUI is running and others require a restart. If there is a icon beside the parameter you need to restart the Avantra WebUI service before changes will take effect.

To adjust WebUI parameters:

  1. Select Administration  Settings from the top-level menu.

    Choose Avantra UI.

  2. Click on and change the value or on to restore the default.

  3. Push the Save button.

WebUI Parameters

a5-listener-port

Set a fixed listener port for Avantra WebUI. Set this port if you want to define a fixed port that is used for Avantra Server to Avantra WebUI communication. Make sure that this port is available! If this port is not set, a dynamic port is used. Set this port if your Avantra Server and Avantra WebUI are not running on the same host and a firewall prevents dynamic ports.

Default Value

Not set

Unit

Integer

availabilities.downtimewindow

The maximum downtime window in seconds for availability processing of Composite Checks and Business Services.

If downtime is greater than this value an Unknown record is written, otherwise, the old record is extended.

Default Value

120

Unit

Seconds

BusinessServicesOverview.ShowTooltips

Defines whether or not tooltips are displayed in the Business Service overview.

Default Value

yes

Unit

Boolean

clientcertusermapping

See Using Client Certificates for Login for a description.

Default Value
Unit

String

customer.label-1 to customer.label-5

Defines the name of customizable additional fields.

When the name of the field is defined, the field is shown in the Customer pages (see also Defining Customers). When the name of the field is missing, the field is not displayed.

Default Value
Unit

String

customer.length-1 to customer.length-5

Defines the length of fields defined through customer.label-1 to customer.label-5 values (maximum 1024).

Default Value

128

Unit

Integer

defaultMonitoringOffTime

Defines the time in hours and minutes (in format HH:MM) used as default values for the Monitor off until date and Monitor off until time field once monitoring is turned off.

Default Value

12:00

Unit

Hours

defaultRtmConfirmTime

Defines the time in hours and minutes (in format HH:MM) used as default values for the Confirm until date and Confirm until time field once monitoring is turned off.

Default Value

12:00

Unit

Hours

help-public-access

Defines whether this document is accessible without login from Avantra WebUI.

Default Value

no

Unit

Boolean

LogLevel

Defines the level of messages to be logged in Avantra WebUI log files in C:\Program Files\syslink\xangui\log ` (on Microsoft Windows operating systems) or `/syslink/xangui/log (on Unix-like operating systems)

Default Value

WARN

Unit

Enum

logon.lockTimeMinutes

The number of minutes a user is locked after a defined number of failed login attempts.

Default Value

5

Unit

Minutes

logon.maxFailedLoginTries

The number of login attempts a user has before being temporarily locked. 0 means an infinite number of login attempts.

Default Value

3

Unit

Number

MaintWindowDefaultMoniSwitch

Allows you to set a default value for creating Maintenance Windows to monitoring on or off.

Default Value

off

Unit

Enum

ntf-test.timeout

Defines the timeout for testing Notification Actions.

Default Value

30

Unit

Seconds

prefix

Defines the content of the title tag of Avantra WebUI HTML pages.

Default Value

Avantra

Unit

String

remember-me

Defines if or if not the Remember Me checkbox is shown on the login page.

Default Value

yes

Unit

Enum

reset-password

Defines if or if not the Forgot Password link is shown on the login page.

Default Value

yes

Unit

Enum

RTMControlCenterDashboard

The Name of the Dashboard that shall be used as RTM Control Center, i.e. which is accessible by Monitoring  RTM Control Center.

Unit

String

rtmuser

The User that is used for the System Dashboards direct URL access. If this value is set, System Dashboards can be accessed without manual login. The value of this property indicates the User used for the automatic login.

If left empty, you need to log in manually to access System Dashboards via the direct URL.

Default Value

rtm

Unit

String

SAPCAR

The full path to the SAPCAR utility used to extract files during automated kernel upgrades, e.g. /syslink/sapcar/SAPCAR_1320-80000935.EXE.

Default Value

empty

Unit

String

SAPLogonSSOEnabled

Enables Single Sign-On (SSO) for the SAP Logon.

Default Value

no

Unit

Boolean

schedule-wait-time

Defines a delay (in seconds) between each group of update-simultaneous-downloads update schedules.

Default Value

60

Unit

Integer

showunassignedchanges

Defines whether or not the number of unassigned Changes is displayed in the Avantra WebUI toolbar.

Default Value

yes

Unit

Booelan

slr.appendid

Defines whether or a unique identifier is appended to a Service Level Report once it is published.

Default Value

yes

Unit

Booelan

ticket.attachmentsToDelete

Defines file extensions of attachments that are removed from Tickets in status Closed after the retention period defined in {_ticket.daystokeepattachments>>-is-expired. Separate multiple extensions with a space. wildcards * and ? are allowed. This parameter is only effective if <<ticket.daystokeepattachments} is set to a value different from 0.

Default Value

.log .zip .tar.gz .tmp .rar .tar .tgz

Unit

String

ticket.daysToKeepAttachments

Defines how long to keep attachments of Tickets in status Closed before they get deleted automatically. If set to 0 attachments are not deleted automatically. Use ticket.attachmentsToDelete to define a list of file extensions that this parameter is effective for.

Default Value

180

Unit

Days

ticket.sendemail

Defines whether emails are sent automatically to Ticket callers and owners after a new ticket log is written. The options are: Always, Never, and Ask.

Default Value

Ask

Unit

List

ticket.updateindex

Defines how often the Ticket list index is updated automatically. The value 0 means no automatic update. Automatic updates are only necessary if Tickets are created through Notification Actions.

Default Value

60

Unit

Minutes

ui-master-protocol

Use a5 or a5s as a protocol for communication between Avantra WebUI and Avantra Server. Set this option to a5s when your Avantra WebUI and Avantra Server are not running on the same host.

Protocol Description

a5

plain communication

a5s

SSL/TLS secured communication

Default Value

a5

Unit

Enum

update-simultaneous-downloads

There is a limit of simultaneous scheduled agent updates. Avantra WebUI will only schedule the defined number of updates at a time in order to restrict the number of concurrent download attempts for the Agent Self Updates.

If more updates are actually requested than defined, the Avantra Server waits schedule-wait-time seconds before scheduling the next ones, etc.

Default Value

8

Unit

Integer

url-replacement

Defines the URL prefix used in the links contained in mails generated.

By default (i.e. empty) the mails contain links as displayed in the browsers location bar.

If you define a URL prefix, the relative UI URL will be appended to this value.

Unit

String

webservice

Defines if the Webservice is available. See Enable/Disable the Avantra Web Service.

Default Value

false

Unit

Boolean

HttpProxyHost

Set an outgoing proxy. If set, this proxy is used for outgoing calls (Notifications, Cloud Services, Activation).

If you need a different proxy for the Activation, use the LicenseActivationHttpProxyHost, LicenseActivationHttpProxyUser and LicenseActivationHttpProxyPassword setting instead.

Format: host. Leave this field empty if no proxy is required.

Unit

String

HttpProxyUser

Defines the user name in case the proxy defined in HttpProxyHost requires authentication.

HttpProxyPassword

Defines the password corresponding to HttpProxyUser.

LicenseActivationHttpProxyHost

Set an outgoing proxy for the Activation. You must only set this if you have different proxies and your primary proxy defined in HttpProxyHost cannot be used for Activation.

Format: host. Leave this field empty if no proxy is required.

Unit

String

LicenseActivationHttpProxyUser

Defines the user name in case the proxy defined in LicenseActivationHttpProxyHost used for Activation requires authentication.

LicenseActivationHttpProxyPassword

Defines the password corresponding to LicenseActivationHttpProxyUser.