Skip to main content
Version: 25.x

BTPCFSpaceQuotasAppProcessInstances

BTPCFSpaceQuotasAppProcessInstances

This check monitors the current number of app process instances against the space total instances quota by listing all spaces, the applications and the number of running instances. A Warning status can be returned if a stopped application would be prevented from starting a quota using CloudFoundryWarnIfAnyStoppedAppWouldExceedQuota.

SpaceQuotasMemMaxMemoryQuotaUsedPercentWarn and SpaceQuotasMemMaxMemoryQuotaUsedPercentCrit monitoring parameters can be used to set Warning and Critical thresholds if the process instances running in applications is above a set percentage of the quota.

Reference Data

Managed SystemCloud Services
Check CycleRealTime Monitoring
Depends onBTPConnect
Monitoring ParametersCloudFoundryWarnIfAnyStoppedAppWouldExceedQuota, CloudFoundryIncludeStoppedAppsInQuotaCalculation, SpaceQuotasAppProcessInstancesMaxInstancesUsedPercentWarn, and SpaceQuotasAppProcessInstancesMaxInstancesUsedPercentCrit