BTPCFSpaceQuotasAppProcessInstances
BTPCFSpaceQuotasAppProcessInstances
This check monitors the current number of app process instances against the space total instances quota by listing all spaces, the applications and the number of running instances. A Warning status can be returned if a stopped application would be prevented from starting a quota using CloudFoundryWarnIfAnyStoppedAppWouldExceedQuota.
SpaceQuotasMemMaxMemoryQuotaUsedPercentWarn and SpaceQuotasMemMaxMemoryQuotaUsedPercentCrit monitoring parameters can be used to set Warning and Critical thresholds if the process instances running in applications is above a set percentage of the quota.
Reference Data
| Managed System | Cloud Services |
| Check Cycle | RealTime Monitoring |
| Depends on | BTPConnect |
| Monitoring Parameters | CloudFoundryWarnIfAnyStoppedAppWouldExceedQuota, CloudFoundryIncludeStoppedAppsInQuotaCalculation, SpaceQuotasAppProcessInstancesMaxInstancesUsedPercentWarn, and SpaceQuotasAppProcessInstancesMaxInstancesUsedPercentCrit |